I have a project where the existing transformer protection relays are old Reyrolle TJM10 induction disc relays. My issue, is i have no idea how these work, and how to go about finding the existing settings and then changing them to something new. Does anyone have any documentation for this relay type, or could you describe it.
IET Digital Library; Wiring Regs digital; IET Electrical 800A ACB & Reyrolle TMJ 10 Earth Leakage Relay Topic Summary: Fitted to old I have just come of the phone with one of their engineers and they think the earth protection relay may be providing restrictive earth fault protection for
relay “Protection Healthy” output is energised whenever the relay is powered-up and working correctly. If the self monitoring feature of the relay detects a hardware fault, or the relay power supply is lost, this contact will drop off. In their normal mode of operation, output contacts remain energised for at least 100ms, or for the duration of
Protection Devices in facilities without reliable auxiliary power supply Reyrolle Application Note APN-001 6 Edition 1 1.4 Summary The use of suited protection devices together with a conformed electrical design is the key to optimize the
See more like this Reyrolle Protection Ngc Sub Rack Rmlg Test Block Rolls Royce Engine. Reyrolle 25v panel mount socket box with switch x 2. New (other) See more like this Reyrolle Protection Relay 283501-2 283501 Rolls Royce Engine Ar101 New* Click & Collect. REYROLLE 7PG1111-2CC10-0AC0
Normal Inverse IDMT Form 1.3/10 Relays Type 2TJM70 Burden 3VA at current setting Time multiplier 0.1 to 1.0, continuously adjustable Pick-up Not greater than 130% of setting Reset Not less than 90% of setting current switched to zero) Overshoot Less than 80ms Contacts 2 normally open self reset
The ?XG?? test equipment allows the monit